COATRON M2
Coagulation Analyzer

two channels, quarter volume

Cat.No. 80 700 00

Reduced reagent and sample volume with same precise and accurate measurements make the routine more cost effective.
This new manual Coagulation analyzer measure all clotting based Coagulation tests with a quarter of the regulary volumes.

Example:
PT: 25µl sample + 50 µl PT-reagent

The Coefficient of Variation (CV) is <2-5% depending on test and reagent used.

The Coefficient of Variation (CV) is <2-5% depending on test and reagent used. A new double cuvette allows an effective and quick work, even for more samples. A unique automatic amplification is especially designed for all new sensitive Thromboplastin reagents and equalize high differences of turbidity from reagents and samples. All specific test parameters are stored in the system.

The Coatron M2 fits perfect into small and medium Coagulation laboratories. For usage in Emergency laboratories this instrument offers all possibilities.

Tests
PT, APTT, TT, Fibrinogen (Clauss and PT derived),
Factor II, V, VII, VIII, IX, X, XI, XII, Fletcher, VT (Venom Time),
APCR, AT-III (clot), Protein C (clot), Protein S (clot), Heparin, STAT (PT/PTT)

Selectable dimensions
seconds, %-Activity, Ratio, INR, Units, g/l, mg/dl

Technical Description
The Coatron M2 is a micro-computer controlled Coagulation instrument with two channels and a LC-Display. The tests will be selected through keys on a foil keyboard. The dialog language is user friendly and selectable in English and German. Other languages can be provided optionally

The Main program offers following menus
  • ANALYSIS
  • SETUP-TEST
  • SETUP-SYSTEM
  • SERVICE
The measurement can be started manually by pressing the OPTIC-key in the same time when reagent is added or with a connected Autopipette. The results are displayed in the measured dimension and can be converted into other desired dimensions by pressing the UNIT-key. A connected printer will automatically print out the results in all dimensions with Optic channel and test name. A patient identification No. can be optionally selected between "NO PAT.ID", "MANUAL ENTRY" and "AUTO-SERIES" with Start No.

Using the TECO Softwaretools the measuring curve data can be transmitted to a Personal Computer and loaded by any spread sheet with graphic function. Software updates are realized with an easy download from a computer to the instrument.

Technical Data

Device SMD Board, V-25 Microcomputer, 18-bit Analog-Digital Converter, 1 MBit Flash-EPROM; 1 MBit E2 PROM,
Power Supply
(external)
Input voltage: 94 to 243 Vac, Input frequency: 50 to 60 Hz, Power output (max): 40 VA,
Approvals: CSA, UL, TÜV-GS, CE-Mark
Optic block 2-channel Optics
Keyboard Foil keyboard, 3x8 matrix, with Test-, Functions- and Numerical keys
Display 4 lines x 20 Characters, Liquid Crystal Display (LCD)
Incubation block 12 prewarming positions, 2 measuring positions,
1 Reagent position, mixed with different adapters,
1 Reagent position Ø 16 mm,
1 Reagent position Ø 22,5mm,
Temperature: 37,0°C ± 0,2°C
Autopipette:
(optional)
4-stage Autopipette with electronical start
Volume: 25/50/100/200 µl
Thermal Printer:
(optional)
external, serial printer with print-out of all results, print-out of test parameters, print-out of system parameters

Standard package
  • 1 Pc Coatron M2
  • 1 Pc Power Supply
  • 1 Pc Mains cable
  • 25 Pcs Double cuvettes
  • 5 Pcs Reagent container
  • 1 Pc Magnetic stirrer
  • 1 Pc Reagent adaptor
  • 1 Pc Printer cable
  • 1 Pc Pipette fastener
  • 1 Pc Operation Manual
  • 1 Pc Warranty card
  • 1 Pc Installation report
  • 1 Pc Service report
Consumables and Accessory
  • 19 000 02 Double cuvettes
  • 19 029 00 4-stage Autopipette
  • 19 030 01 Reag.adaptor Ø 22,5mm
  • 19 030 02 Reag.adaptor Ø 22,8mm
  • 19 030 03 Reag.adaptor Ø 24,2mm
  • 19 030 04 Reag.adaptor Ø 27,8mm
  • 19 030 05 Reag.adaptor Ø 25,2mm
  • 80 050 06 Stirring magnets
  • 80 525 00 Reagent container
  • 80 530 00 Reagent tubes
  • 80 535 00 Thermal printer
  • 80 920 07 Pipette tips
  • 80 920 12 Thermal paper
  • 80 920 14 Printer cable

Reagents
  • TEClot reagents (PT, APTT, TT, FIB, VT, LA, PC, PS)
  • TECal Normal and Abnormal
  • TEControl N, A1, A2, LA+, PC, PS etc.
  • Deficient Plasmas

Important advantages
  • all clotting tests in one system
  • quarter volume for less price/test
  • Research capabilities
[ Download certificate (PDF-File) ]